📚 Technical Articles

Knowledge Base › Selection Error Cases › Excessive screw pre-tension causing bearing overload (large gantry milling machine)

Excessive screw pre-tension causing bearing overload (large gantry milling machine)

E41-190 · Screw Selection · Large Gantry Milling Machine Screw Pre-Tension · ★★★

Problem Description

After screw pre-tensioning, the fixed-end bearing temperature rose to 75℃ in operation (normal ≤50℃), and the bearing life dropped from 8000h to 1200h.

Root Cause

The screw pre-tension force F_pre=σ_pre×A=50×10⁶×π×0.025²≈98kN. The fixed-end angular-contact ball bearing (7214AC) has a dynamic load rating C=72kN. Since 98kN > 72kN, the bearing is already overloaded under pre-tension! The axial force on the bearing = pre-tension + cutting force = 98+5 = 103kN, far exceeding the dynamic load rating. The ball-to-raceway contact stress σ_H=0.388×√(103000×206000²/7²)≈3200MPa (allowable ≤2000MPa); the raceway shows overload plastic deformation and life drops sharply.

Corrective Solution

① Pre-tension force should be ≤70% of the bearing dynamic load rating\n② Here the 98kN pre-tension must be reduced to 72×0.7≈50kN\n③ Reduce the pre-tension amount: δ_pre=F_pre×L/(E×A)≈50×10³×1500/(206000×π×25²)≈0.185mm\n④ Use a paired bearing set (DB arrangement, C=2×72=144kN, can sustain 98kN)\n⑤ Or switch to a cylindrical roller bearing (N series, strong radial-load capacity)

Checklist

Reference

FT_11 Ball Screw Selection

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL