E41-563 · Gearbox & Coupling Selection · Cycloidal Speed Reducer Clearance Too Small · ★★★★
A cycloidal speed reducer was stiff when turned by hand after assembly, and after two hours of no-load running the temperature reached 85℃. On disassembly the clearance between the cycloidal wheel and the pin tooth housing was found to be only 0.02mm (standard 0.05~0.10mm).
The clearance between the cycloidal wheel and the pin tooth housing (which allows the cycloidal wheel to orbit in the housing without interference) has a standard value of 0.05~0.10mm. The actual clearance was 0.02mm (60% too small). In operation the small clearance causes the outer rim of the cycloidal wheel to contact the inner wall of the pin tooth housing (metal-to-metal friction), generating friction heat Q=μ×F×v=0.1×500×2=100W (μ=0.1, contact force F≈500N, sliding velocity v=2m/s). This 100W of friction heat raised the reducer temperature by 60℃ in two hours (from 25℃ to 85℃). The contacting surfaces of the cycloidal wheel (GCr15, HRC60) and the pin tooth housing (38CrMoAl, nitrided HV900) reached about 200℃, forming a blue oxide film and producing adhesive wear (galling). After the cycloidal wheel rim had worn by about 0.01mm the clearance increased and the friction disappeared, but an irreversible loss of accuracy had already occurred.
1) Standard assembly clearance between the cycloidal wheel and the pin tooth housing: 0.05~0.10mm (check with a feeler gauge);
2) Measure the cycloidal wheel outside diameter and the pin tooth housing bore before assembly (to calculate the clearance);
3) If the clearance is too small, lap the outer rim of the cycloidal wheel or bore the pin tooth housing out;
4) After assembly the reducer should turn by hand without stiffness, with a rotation torque ≤1Nm;
5) A 2h no-load trial run should give a temperature ≤45℃.
FT_13_Gearbox and Motor Matching Selection