E41-107 · Sensor Electrical Selection · Servo Drive Position Feedback · ★★★★
When the servo motor runs at high speed (3000 rpm), the position-feedback signal shows periodic jumps, the motor jitters, and chatter marks appear on the machined surface.
The encoder cable was a standard shielded cable (single-layer copper-braid shield, 80% coverage) routed parallel to the power cable in the same tray (spacing only 5 mm). The VFD output cable (PWM pulses, 4 kHz carrier) generates a strong electromagnetic field; the induced interference voltage coupled onto the encoder cable is U_ind = M×di/dt = 0.1 μH × 2000 A/μs ≈ 0.2 V. Although small in amplitude, an RS-422 differential receiver with a trigger voltage as low as 5 V produces bit errors under common-mode interference. Meanwhile the encoder cable shield is grounded at only one end (single-ended grounding), so high-frequency interference forms a loop through distributed capacitance, further degrading signal quality.
① Keep encoder and power cables ≥300 mm apart; never route them in the same tray
② Use a double-shielded encoder cable (copper braid plus aluminum foil, 100% coverage)
③ Ground the shield at both ends (drive end plus motor end, grounding impedance ≤4 Ω)
④ Add ferrite cores (wind the cable three turns through ferrite rings at both ends)
⑤ Use a fiber-optic encoder (optical transmission, fully immune to electromagnetic interference)
FT_33_Sensor Selection Guide