E41-307 · Other Selection · Equipment Anchor-Bolt Grouting · ★★★
The anchor bolts of a compressor unit loosened after 3 months of operation, and the secondary grout cracked and fell off. The grout strength was only C15 (design C35).
The secondary grouting for the anchor bolts used ordinary cement mortar (water-cement ratio 0.55) instead of a dedicated grout (C35 non-shrink grout required). Ordinary cement mortar has a shrinkage of about 0.1%, creating a gap of about 0.05mm between it and the foundation/base plate after hardening (shrinkage + thermal deformation). Under compressor vibration (amplitude 0.02mm), the gap between the grout layer and the base plate gradually widened, and the grout layer eventually cracked and fell off. The anchor bolts loosened after losing their constraint. The loose bolts shifted the compressor base, widening the coupling alignment deviation from 0.05mm to 0.2mm and accelerating wear of the coupling elastomer.
① For secondary grouting of equipment, a dedicated non-shrink grout (C35~C45) must be used\n② Before grouting, chisel the foundation surface (remove the laitance layer and expose the coarse aggregate)\n③ Mix the grout per the manufacturer's proportions (water-cement ratio ≤0.4)\n④ Cure for ≥7 days after grouting (cover with wet cloth + sprinkle water)\n⑤ Tighten the anchor bolts only after the grout strength reaches 70% of the design value (usually after 3 days)