Gas spring support-force decay causing the access cover not to lift (equipment service door)

E41-471 · Other Selection · Gas Spring Support-force Decay · ★★★

Problem Description

The gas spring (model YQ-8/22, support force 800 N) on an equipment service door dropped to about 400 N after 2 years and could no longer lift the service door (weight 15 kg).

Root Cause

The gas spring (compressed N₂, initial pressure about 15 MPa) slowly leaks through the piston-rod seal (NBR) during long-term use, gas escaping gradually. Leak rate about 0.5%/month (standard allows ≤1%/year); over 2 years cumulative leakage about 12%. Gas pressure dropped from 15 MPa to about 13.2 MPa, support force F = P×A = 13.2×10⁶×π×0.008² ≈ 2653 N (piston rod Φ16 mm), far above 400 N. This shows reduced cylinder pressure was not the main cause. The damping oil (silicone oil) also leaked from the seal (about 5 ml/year); after oil loss the damping force during compression/release dropped, but support force should not decrease. Actual cause of reduced support force: the piston rod surface rusted during long-term exposure (chrome plating wore, exposing carbon-steel substrate which rusted), rust particles entered the seal → seal wear → accelerated gas leakage. Maintenance did not clean and lubricate the piston rod regularly.

Corrective Solution

① Clean and lubricate the gas spring piston rod regularly (apply silicone oil monthly, for rust protection and lubrication).\n② Use a gas spring with stainless-steel piston rod (complete rust protection).\n③ Gas spring service life: standard 3–5 years (by frequency and environment).\n④ Support-force check: once per quarter; replace when below 80% of rated.\n⑤ Fit a dust cover in harsh environments (reduce piston-rod contamination).

Checklist

Reference

FT_Machine Design Handbook