Excessive Pipe Support Spacing Causes Pipeline Vibration and Fracture (Pipe Support)

E41-758 · Other Selection Topics · Pipe Support Spacing and Pipeline Fracture · ★★★★

Problem Symptom

A compressed air pipeline (DN50 galvanised pipe, 15m long) vibrated violently when the air compressor started. The pipe clamp spacing was 2.5m and the weld of one clamp was torn open.

Root Cause

The natural frequency of a pipeline depends on the clamp (support) spacing. For a DN50 pipe the weight is q=5kg/m and the stiffness EI=2.06×10¹¹×π×(0.057⁴-0.053⁴)/64=206×10⁹×(1.47×10⁻⁶)=303N·m². The natural frequency of a single span is fn=π/2×√(EI/(m×L⁴))/(2π)=√(303/(5×2.5⁴))/(2)=√(303/195.3)/2=1.245/2=0.62Hz (which is not right; the formula should be fn=π/2×√(EI/(mL⁴))). For L=2.5m, fn=π/2×√(303/(5×39.06))=1.57×√1.55=1.57×1.245=1.95Hz. The charging process when the compressor starts generates pressure pulsations of about 2~3Hz, which is close to the natural frequency of the pipeline at 1.95Hz, so resonance occurs. The amplitude A=Q/(2×m×ω_n×ζ) is about 0.5mm (Q the amplitude of the exciting force). For the 15m pipe (six spans, amplitude 0.5mm → 0.05mm at the clamps, accumulating over the six spans) the dynamic stress at the clamps is σ_d=3×E×D×A/L²=3×206000×57×0.05/2500²=3×206000×57×0.05/6.25×10⁶=0.028MPa, which is very small. The clamp weld actually tore open because the clamp was welded to a thin-walled galvanised pipe (the galvanised coating degrades the weld quality), so the effective weld thickness was only 2mm against a design 4mm, and the weld developed fatigue cracks under vibration (fracturing after about 10⁶ cycles).

Correct Solution

1) Re-check all the parameters against the correct selection specification;
2) Confirm that the duty load, environment and life all meet the design requirements;
3) Select a reliable brand and a suitable model;
4) Verify the installation and operating conditions;
5) Inspect and maintain the equipment at regular intervals after commissioning.