E41-786 · Other Selection · Flange Tightening Distortion · ★★★
After tightening, the pump inlet/outlet flange (DN100, 8 bolts) distorted (flatness worsened from 0.1 mm to 0.3 mm) and the gasket failed, leaking.
The flange bolts were not tightened in diagonal order (tightened sequentially 1-2-3-4-5-6-7-8); the first-tightened bolts skewed the flange (one-sided force). When bolt 1 was tightened (torque 200 Nm), that side of the flange was pulled in and the other side lifted (gap about 0.15 mm). Tightening later bolts, the lifted side needed more travel to press the flange, but the bolt group already had uneven preload: the first bolt about 150 kN (overload), the last only 50 kN (insufficient). Under non-uniform preload the flange warped (flatness 0.3 mm); the gasket (PTFE, 3 mm thick) compressed unevenly, and at the low-pressure spot (0.3 MPa sealing stress < 5 MPa) it leaked.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook