E41-820 · Other Selection · Isolator Frequency Mismatch · ★★★★
The fan (speed 1450 rpm) used rubber isolators (natural frequency 20 Hz); after installation the fan vibration dropped from 2 mm/s to 1.8 mm/s (only a 10% reduction).
The fan excitation frequency f = 1450/60 = 24.2 Hz. The isolator natural frequency f_n = 20 Hz. Frequency ratio λ = f/f_n = 24.2/20 = 1.21. The isolator transmissibility η = √((1+(2ζλ)²)/((1-λ²)²+(2ζλ)²)) − 1 ≈ √(1.24)/(0.53) − 1 = 1.11/0.53 − 1 = 1.1 (at λ = 1.21 the transmissibility > 1, so the isolator actually amplifies vibration!). An isolator has isolation effect only when λ ≥ √2 = 1.414, i.e. f_n ≤ f/1.414 = 24.2/1.414 = 17.1 Hz. The selected isolator f_n = 20 Hz > 17.1 Hz operates in the resonance region (transmissibility ≈ 1.1), with no isolation effect. An isolator with f_n ≤ 17 Hz should be chosen (e.g. a spring isolator, f_n = 5–10 Hz), or a rubber isolator with reduced hardness (f_n lowered from 20 to 15 Hz).
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook