E41-821 · Other Selection · Inaccurate Torque Wrench · ★★★
A torque wrench (range 0–300 N·m, set value 200 N·m) was used to tighten the foundation bolts, but actual preload inspection found only 150 N·m (deviation −25%).
The torque wrench (preset type, mechanical scale) was not sent for calibration within 2 years; internal spring fatigue caused output torque deviation (creep lowered the spring stiffness, so actual output torque was below the set value). The torque wrench calibration interval is 6 months or 5000 uses; in practice it had been used 2 years, about 8000 times, far exceeding the interval. The −25% deviation (200 N·m set, actual 150 N·m) reduced the bolt preload from the design 200 kN to 150 kN (a 25% drop), making the bolts prone to loosening under equipment vibration.
① Recheck all parameters per correct selection specifications
② Confirm that operating loads, environment, and service life all meet design requirements
③ Select reliable brands and appropriate models
④ Verify installation and operating conditions
⑤ Perform periodic inspection and maintenance after commissioning
FT_Machine Design Handbook