Problem Description

One steam pipe (1.6 MPa, 200°C) used a plain rubber-asbestos gasket in place of the designed spiral-wound gasket; it creep-relaxed and leaked steam in service.

Root Cause

First, rubber-asbestos gaskets have high high-temperature creep; at 200°C permanent compression set >30%, preload decays. Second, creep drops flange face pressure y below y_p, opening a gap and leaking. Third, steam leakage wastes energy and is hazardous. Root cause: insufficient gasket temperature/creep resistance.

Corrective Solution

① Steam/high-temperature flanges must use spiral-wound or serrated composite gaskets
② Select gaskets by temperature-pressure rating (GB/T4622)
③ Do not use plain rubber gaskets for steam above 150°C
④ Select low-creep gaskets (graphite-filled spiral-wound)
⑤ Hot-tighten to compensate for creep
⑥ Do not substitute wrong types
⑦ If steam leaks, check gasket type immediately