E41-893 · Seal Component Selection · Boiler Feed Pump · ★★★★★
One feed pump's mechanical seal flush line was clogged; faces had no fluid film and ran dry, temperature >300°C, cracking; the pump leaked and the boiler shut down.
First, a mechanical seal relies on flush fluid to form a film on the faces and carry away friction heat; if flush stops, friction heat Q cannot be dissipated. Second, dry running under face pressure p_b raises temperature ΔT=Q/(m·c) above 300°C, thermally cracking the silicon carbide ring. Third, cracking leaks and the boiler shutdown loses production. Root cause: flush system failure.
① Mechanical seals must have a flush/cooling system (API682 plan) with flow and pressure meeting spec
② Add filtration + flow interlock on the flush line; alarm on loss
③ Select the flush plan by medium temperature (PLAN11/21/32)
④ Select temperature-resistant face materials (SiC/carbide)
⑤ Add face temperature monitoring
⑥ Do not run without flush
⑦ Clear flush lines periodically