E41-894 · Seal Component Selection · Centrifugal Pump with Mechanical Seal · ★★★★

Problem Description

One centrifugal pump lost suction at the inlet and ran dry; the mechanical seal ran dry for 3 minutes, burned out and leaked, and the pump shaft seized.

Root Cause

First, a mechanical seal relies on the medium to lubricate and form a hydrodynamic film; running dry means no fluid → dry friction. Second, dry-running friction coefficient μ rises from 0.02 to 0.3, heat flow Q∝μ surges 15×, face temperature rises >200°C, and faces score. Third, burnout in 3 minutes and shaft seizure. Root cause: dry running.

Corrective Solution

① Mechanical seal pumps must not run dry; install inlet level/flow interlocks to stop the pump
② Select dry-running-rated seals (SiC vs. SiC, or self-lubricating coating) only for short dry periods
③ Install a foot valve/prime at the inlet to prevent cavitation loss of suction
④ Add dry-run monitoring (vibration/temperature)
⑤ Prime and vent the pump before start-up
⑥ Do not start without liquid
⑦ If the seal burns, investigate loss of liquid immediately