Non-Post-Weld-Annealed Weld Joint Causes Fatigue Cracking in the Heat-Affected Zone

E42-008 · Fatigue Fracture · Welded Frame Main Beam · ★★★

Problem Symptom

Cracks propagate in the weld heat-affected zone after 2 years of running, creating a load-bearing hazard

Root Cause

[Residual Stress] After welding, the HAZ residual tensile stress σ_r≈0.8σ_s=400MPa; combined with the working stress σ_w=150MPa the total is σ=550MPa.
[Fatigue Damage] Under 550MPa alternating stress ΔK exceeds the threshold, and the crack growth rate da/dN=2e-8mm/cycle brings the crack to critical size in 2 years (6e7 cycles).
[Design Omission] No post-weld annealing was performed and the HAZ was not ground, leaving a crack hazard.

Correct Solution

1) Anneal the whole assembly after welding to eliminate residual stress;
2) Grind the HAZ to Ra3.2 to remove undercut;
3) Perform 100% magnetic-particle inspection of the welds;
4) Change to double-sided bevels to reduce restraint;
5) Carry out fatigue grading of load-bearing welds;
6) Set up regular inspection of the crack path;
7) Fit strain gauges on critical welds for monitoring;
8) Make post-weld annealing a mandatory node in the welding procedure.

Checklist

References

GB/T 12467 Quality Requirements for Welding

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »