Problem Description

After 400,000 km the spring fractures; free height drops 15mm.

Root Cause

[High Stress Amplitude] Wire d=30mm, 6 active coils; dynamic deflection ±30mm makes τ_a=520MPa exceeding check. [Surface Defect] Insufficient shot peening; decarburized layer 0.08mm acts as source. [Design Omission] No fatigue spectrum check; safety factor 1.3 (should be ≥1.8); 120 vehicles recalled.

Corrective Solution

1. Increase wire diameter from 30mm to 34mm.
2. Reduce active coils from 6 to 5 to lower stress amplitude.
3. Shot peening coverage ≥98%, intensity 0.4-0.5mmA.
4. Control decarburized layer to ≤0.02mm.
5. Perform fatigue check per route spectrum, n≥1.8.
6. Both end faces parallel ground to ≤0.05mm.
7. Piece-by-piece load-deflection characteristic test.
8. Magnetic-particle inspection every 100,000 km in service.