Knowledge Base › Structural Design Error Case Study › Fillet Weld End Without Wrap-Around Causing End Tear

Fillet Weld End Without Wrap-Around Causing End Tear

E42-220 · Welding Deformation and Defects · Bracket Fillet Weld · ★★★

Problem Description

After loading, fillet weld end cracks; tear 25mm long.

Root Cause

[End Stress] Fillet weld arc-crash end without wrap-around weld forms crater stress concentration K_t=3. [Tear Propagation] Under load crater crack propagates 25mm and tears open. [Design Omission] No wrap-around weld specified; end not ground.

Corrective Solution

1. Fillet weld end wrap-around weld ≥10mm.
2. Fill crater on arc-crash and grind flush.
3. Leg size per 1.2t.
4. Magnetic-particle inspect end.
5. Make load-bearing fillet welds double-sided.
6. Welder technical briefing.
7. Sample end inspection each batch.
8. Add reinforcement plate on critical parts.

Checklist

Reference

GB/T 50661-2011

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »