Knowledge Base › Structural Design Error Case Study › Thick Plate Insufficient Post-Weld Peening Causing Residual Stress Delayed Crack

Thick Plate Insufficient Post-Weld Peening Causing Residual Stress Delayed Crack

E42-267 · Welding Deformation and Defects · Thick Plate Box Girder · ★★

Problem Description

Thick plate box girder (δ=40mm) delayed crack 120mm long appears after standing; 3 pieces reworked per month

Root Cause

[Residual Stress] No peening for stress relief after welding; longitudinal residual stress σr=350MPa near yield σs=390MPa.
[Delayed Crack] Diffusible hydrogen [H]=8mL/100g (should be ≤3); hydrogen accumulation + stress superposition; cracks along fusion line after 48h.
[Design Omission] No dehydrogenation; no peening; safety factor 1.2 (should be ≥1.8); no low-hydrogen electrode.

Corrective Solution

1) Peen each layer after welding for stress relief;
2) Preheat 120℃ before welding; interpass ≥100℃;
3) Post-weld dehydrogenation 250℃×2h;
4) Bake low-hydrogen electrode at 350℃;
5) Overall post-weld annealing to relieve stress;
6) UT inspect cracked zone;
7) Measure hydrogen content each batch ≤3mL/100g;
8) Control ambient humidity ≤60%.

Checklist