E42-461 · Welding Deformation and Defects · Box Girder Diaphragm · ★★
Box girder (height 1200) diaphragm electroslag weld lack of fusion 200mm long; load capacity reduced; 1 piece scrapped per month
[Lack of Fusion] Electroslag weld heat input q=40kJ/cm; fast cooling gives 200mm long lack of fusion.
[Weak] Effective thickness reduced; load capacity drops.
[Design Omission] Slag pool temperature not controlled; no flaw detection; safety factor 1.3 (should be ≥2.0).
1) Control slag pool temperature at 1150℃;
2) Raise heat input to 55kJ/cm;
3) Preheat 120℃ before welding;
4) UT inspect after welding;
5) Inspect fusion per seam;
6) Add run-on tab;
7) Grind weld;
8) Periodic re-measurement.
GB/T 50661-2011