MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
Knowledge Base › Structural Design Error Cases › Insufficient Riser Causes
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Insufficient Riser Causes Incomplete Feeding and Shrinkage Cavity

E42-015 · Casting Defects · Large Gear Blank (42CrMo) · ★★★

Problem Symptom

Shrinkage cavity Φ10mm at the gear hub center, scrapped by NDT

Root Cause

[Riser Feeding Volume] The volume to be fed is V_need≈π×5²×10=785mm³, but the existing riser provides only V=600mm³, which is 0.76 times the requirement and therefore insufficient.
[Modulus Check] The riser modulus M_r=V/A=600/180=3.3, below 1.2× the hot-spot modulus 1.2×3.2=3.84, so directional solidification fails and the feeding channel closes early.
[Design Omission] The riser size was chosen by experience without a modulus check, scrapping the hub.

Correct Solution

1) Raise the riser modulus to ≥1.2× the hot-spot modulus (change to V≥900mm³);
2) Add insulating riser sleeves to delay solidification;
3) Place chill irons at the hot spot to accelerate solidification of the surroundings;
4) Verify directional solidification with ProCAST simulation;
5) Perform ultrasonic inspection of the center;
6) Optimise the riser cutting process;
7) Perform first-article sectioning inspection;
8) Include the riser modulus check-up in the casting process review.

Checklist

References

GB/T 37400 Castings for Heavy Machinery

Related 3D models: Ready to build it? Download free 3D models & CAD drawings at MOULDL »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL