Knowledge Base › Structural Design Error Case Study › Blowhole Leakage on Valve Body

Blowhole Leakage on Valve Body

E42-393 · Casting Defects · Cast Steel Gate Valve Body · ★★★

Problem Description

The cast-steel gate valve body flange face has blowholes and leaks on pressure test; 3 parts scrapped per month

Root Cause

[Blowhole] Air entrained in the gating, cluster of Φ3 blowholes.
[Leakage] Sealing face penetrated.
[Design Omission] No vent channels, pouring too fast; safety factor 1.4.

Corrective Solution

1) Add vent channels in the gating;
2) Control pouring speed;
3) Argon-protect the cavity;
4) Pressure-test each valve housing;
5) RT sampling;
6) Optimize risers;
7) Standardize weld repair;
8) Section the first piece.