E42-394 · Casting Defects · Double-Suction Pump Casing · ★★
The double-suction pump casing interior has slag inclusions, cracking and leaking in service; 2 units repaired per month
[Slag Inclusion] Slag entrained during pouring, cracks along the slag line.
[Crack Leak] Slag causes stress concentration.
[Design Omission] No slag trapping, no slag filter screen; safety factor 1.4.
1) Add a slag filter screen in the sprue;
2) Design a slag-trapping cap;
3) Improve pouring steadiness;
4) RT each casing;
5) Pressure leak test;
6) Upgrade material grade;
7) Standardize weld repair;
8) Section the first piece.
GB/T 5657-2013