E42-276 · Heat Treatment Distortion and Cracking · 40Cr Drive Shaft · ★★
The 40Cr drive shaft after quenching has surface hardness only 42HRC (should be ≥50), wearing fast in service; 9 shafts replaced per month
[Medium Aging] Quench oil not changed for years; characteristic temperature dropped from 480℃ to 420℃ and cooling rate dropped 30%, giving insufficient surface hardness.
[Under-Hardened] Large core-to-surface temperature difference; effective hardened layer only 1mm (should be ≥2mm); surface 42HRC below the wear threshold.
[Design Omission] Medium cooling curve not measured, oil not changed; safety factor 1.2 (should be ≥1.6).
1) Measure the quench oil cooling curve quarterly (characteristic temperature ≥460℃);
2) Change aged oil promptly;
3) Raise quenching temperature by 20℃ to 860℃;
4) Add agitation so flow velocity ≥0.5m/s;
5) Sampling surface hardness ≥50HRC each batch;
6) Measure hardened case depth ≥2mm;
7) Control medium temperature at 60±5℃;
8) Re-verify by sectioning the first piece.
GB/T 16923-2008