Problem Description

The coordinate surface plate (1000×1500) distorts 0.03mm after 3 months of storage, exceeding precision-flatness allowance and drifting accuracy; 5 parts reworked per month

Root Cause

[Insufficient Aging] Aged only 4h (should be ≥12h); residual stress σ=60MPa not relieved.
[Drift] After 3 months storage, distortion 0.03mm exceeds precision-flatness allowance 0.01mm; accuracy downgraded.
[Design Omission] Not fully aged, not stress-relieved; dimensional stability only IT7 (should be IT5).

Corrective Solution

1) Age ≥12h;
2) Heat to 180℃ and hold;
3) Natural aging ≥30 days as alternative;
4) Separate rough and finish machining by ≥7 days;
5) Measure residual stress ≤20MPa each batch;
6) Store and recheck stability;
7) Freeze the process;
8) Long-term tracking of the first piece.

Checklist

Reference

JB/T 7974-1999