Knowledge Base › Structural Design Error Case Study › Brittle Fracture of Spring Wire After Patenting Lead Bath

Brittle Fracture of Spring Wire After Patenting Lead Bath

E42-480 · Heat Treatment Distortion and Cracking · Spring Steel Wire · ★★

Problem Description

Spring steel wire (φ10, 60Si2Mn) brittle-fractures after lead-bath patenting and is scrapped in batches; 1 batch scrapped per month

Root Cause

[Brittle Fracture] Bath temperature 480℃ too low; insufficient sorbitization makes it brittle.
[Fracture] Poor ductility.
[Design Omission] Bath temperature not controlled, no inspection; safety factor 1.3 (should be ≥2.0).

Corrective Solution

1) Control lead bath temperature to 500-520℃;
2) Fully sorbitize;
3) In-line hardness inspection;
4) Reduce phosphorus content;
5) Tensile test each batch;
6) Control cooling;
7) Upgrade material purity;
8) Periodic re-measurement.

Checklist

Reference

GB/T 1222-2016