Problem Description

After 20,000 pulse cycles the fitting root cracks and seeps oil.

Root Cause

[Root Concentration] Tube-fitting thread runout sharp corner K_t=3; pulsating σ_a=90MPa. [Fatigue] Root becomes the source; cracks after 20,000 cycles. [Design Omission] No radius transition, surface not controlled; leakage.

Corrective Solution

1. Set R1 radius at the thread runout.
2. Roll-stress the root to reduce the source.
3. Lower pulsating σ_a to 60MPa.
4. Increase fitting wall thickness to ≥3mm.
5. Surface roughness Ra1.6.
6. Pulse test to 2.5× life.
7. Lap threads to prevent off-center load.
8. Sample pulse endurance each batch.