Thermal Cycling of a Welded Frame Causes Local Residual Tensile Stress and Cold Cracking

E42-077 · Thermal Distortion & Thermal Stress · Welded Frame Q345 · ★★★

Problem Symptom

Cold cracking after welding

Root Cause

[Thermal Cycle] The weld cools rapidly and the local tensile stress σ=250MPa exceeds the yield strength.
[Cold Cracking] Restraint plus hardening plus tensile stress produces cracking after welding.
[Design Omission] No preheat and no stress-relief annealing were applied, so the frame cracked.

Correct Solution

1) Preheat to 100-150℃ before welding;
2) Stress-relief anneal at 600℃ after welding;
3) Use low-hydrogen electrodes;
4) Calculate the restraint rigidity;
5) Insulate for slow cooling;
6) Inspect by MT;
7) Use a symmetric welding sequence;
8) Include the heat treatment in the WPS.

Checklist

References

GB/T 19866-2003 Welding Procedure Specification