E42-028 · Corrosion Failures · Outdoor Flange Bolt · ★★★
Bolts seized and fractured after 2 years of running, causing leakage
[Crevice Mechanism] A gasket gap δ<0.1mm forms a closed cell in which Cl- enriches and acidifies the solution.
[Corrosion Rate] The crevice corrosion rate is 0.3mm per year, so an M16 bolt seizes within two years.
[Design Omission] Stainless steel or coating was not used and no sealing was applied, so the bolts seized and leaked.
1) Change the bolts to 316 stainless steel;
2) Fill the crevice with sealant;
3) Add anti-corrosion gaskets;
4) Apply a Dacromet surface coating;
5) Provide drainage to prevent water accumulation;
6) Carry out regular anti-corrosion maintenance;
7) Provide material certificates;
8) Include a corrosive-environment assessment in outdoor connection design.
GB/T 10125 Salt Spray Tests