Galvanic Corrosion Destroys the Contact Between Dissimilar Metals

E42-029 · Corrosion Failures · Aluminium Housing with Steel Screws · ★★★

Problem Symptom

Pitting 2mm deep in the aluminium part at the contact interface

Root Cause

[Galvanic Couple] Aluminium (anode, E=-0.8V) against steel (cathode, E=-0.5V) gives a potential difference of 0.3V and forms a galvanic cell.
[Corrosion Amount] The current i=ΔE/R gives an aluminium dissolution rate of 0.2mm per year, i.e. 0.4mm over two years (measured 2mm including crevice effects).
[Design Omission] The parts were not insulated and compatible materials were not selected, so pitting occurred.

Correct Solution

1) Insert an insulating washer between dissimilar metals;
2) Change to materials of similar potential;
3) Form an anodised film on the contact surface;
4) Apply a primer coat for isolation;
5) Design drainage so no water collects;
6) Conduct regular corrosion patrol inspection;
7) Issue a material compatibility table;
8) Include galvanic compatibility in assembly design review.

Checklist

References

GB/T 5776 Corrosion of Metals