E42-030 · Corrosion Failures · Chemical Pump Casing (304) · ★★★
Pitting perforation and leakage in a chloride-containing medium
[Pitting Potential] In 304 stainless steel with Cl->200ppm the pitting potential Eb is exceeded.
[Perforation Rate] The pitting pit depth grows at 0.5mm per year, so a 6mm wall perforates in two years.
[Design Omission] The wrong material was selected (316L required) and chloride was not controlled, so perforation occurred.
1) Change to 316L or duplex stainless steel;
2) Control the chloride content of the medium to ≤50ppm;
3) Apply passivation treatment;
4) Add 2mm of corrosion allowance to the wall;
5) Measure wall thickness online;
6) Open the casing for periodic inspection;
7) Provide material certificates;
8) Include a media corrosion assessment in pump casing material selection.
GB/T 3280 Cold-Rolled Stainless Steel