E42-079 · Corrosion Failures · Bridge Crane Tie Rod 40Cr · ★★★
The tie rod fractured in a chloride environment
[SCC] Tensile stress plus a Cl- environment initiates a crack which propagates to fracture.
[Fracture] The threshold KISCC is low and the rod fractured after 2 years of service.
[Design Omission] Corrosion-resistant steel was not selected and no protective coating was applied, so the rod broke.
1) Change the tie rod to stainless steel or galvanised steel;
2) Apply a sealing protective coating;
3) Perform regular non-destructive testing;
4) Control humidity and chloride in the environment;
5) Stress-relief anneal to reduce residual stress;
6) Reduce the stress amplitude;
7) Apply cathodic protection;
8) Include the SCC check-up in the design.
GB/T 10125-2021 Artificial Atmosphere Corrosion Tests