Liquid Trapped in a Chemical Pump Flange Gap Causes Crevice Corrosion and Rust-Through

E42-080 · Corrosion Failures · Chemical Pump 304 · ★★

Problem Symptom

The flange gap rusted through

Root Cause

[Crevice Corrosion] Liquid collects in the flange gap and an oxygen concentration cell causes corrosion.
[Rust-Through] In 2 years the 6mm wall was corroded through.
[Design Omission] No drainage design and no corrosion-resistant gasket were used, so the part rusted through.

Correct Solution

1) Add drain holes to the flange;
2) Use corrosion-resistant gaskets (PTFE);
3) Fill the gap with sealant;
4) Upgrade the material to 316L;
5) Drain and flush periodically;
6) Apply a protective coating;
7) Add wall thickness margin;
8) Include the crevice design in the review.

Checklist

References

GB/T 5656-2008 Centrifugal Pumps — Technical Conditions