Chromium Depleted Weld Zone Causes Intergranular Corrosion Cracking of the Tank

E42-129 · Corrosion Failures · Stainless Steel Tank Weld Seam · ★★★

Problem Symptom

Intergranular corrosion cracks in the weld heat-affected zone with leakage

Root Cause

[Chromium Depletion] The welding thermal cycle causes Cr23C6 to precipitate at the grain boundaries and the chromium-depleted zones form, reducing the corrosion resistance.
[Cracking] The medium attacks along the chromium-depleted grain boundaries and intergranular cracks develop.
[Design Omission] Ultra-low-carbon or stabilised steel was not used and no post-weld solution treatment was applied.

Correct Solution

1) Change to ultra-low-carbon steel or Ti/Nb stabilised steel;
2) Apply solution or stabilisation heat treatment after welding;
3) Weld with low heat input at high speed;
4) Match corrosion-resistant consumables;
5) Carry out an intergranular corrosion test (oxalic acid etch);
6) Inspect the weld seams by PT;
7) Assess corrosion for the media operating conditions;
8) Include intergranular corrosion in the welding specification.

Checklist

References

GB/T 4334 Stainless Steels — Intergranular Corrosion Test