Knowledge Base › Structural Design Error Case Study › Valve Internal Leakage Caused by Seal Surface Wear Corrosion

Valve Internal Leakage Caused by Seal Surface Wear Corrosion

E42-179 · Corrosion Failure · Chemical Globe Valve · ★★

Problem Description

Valve seat seal surface pitted 0.5mm deep, internal leakage.

Root Cause

[Wear Corrosion] Medium contains solid particles, erosion and corrosion acted synergistically, seal surface lost luster and pitted. [Internal Leakage] Line seal destroyed, leakage exceeded the limit. [Design Omission] No hard alloy surfacing and no flow velocity control; internal leakage.

Corrective Solution

1. Surface-weld hard alloy Stellite on the valve seat.
2. Control medium flow velocity ≤3m/s.
3. Add a filter upstream.
4. Lap the seal surface to Ra0.4.
5. Add cathodic protection.
6. Regularly lap the seal surface.
7. Add corrosion inhibitor to the medium.
8. Online monitoring of internal leakage.

Checklist

Reference

GB/T 12224-2015

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »