E42-247 · Corrosion Failure · Aluminum water tank bracket bolt · ★★★
After one year of service, steel bolts suffered galvanic corrosion with aluminum and fractured from rust.
[Galvanic corrosion] Steel bolt (cathode) - aluminum bracket (anode) with 0.8V potential difference; under electrolyte the aluminum anode dissolves. [Rust fracture] The aluminum becomes porous and the bolt loses clamping and fractures. [Design Omission] No insulation, no same-material selection, no coating.
1. Change bolts to aluminum or anodized steel.
2. Add insulating bushings between steel and aluminum.
3. Coat contact faces with sealant to block moisture.
4. Anodize the bracket.
5.Inspect corrosion quarterly.
6.Replace critical parts with titanium bolts.
7.Drain to prevent pooled liquid.
8.Corrosion monitoring points.
GB/T 6892-2015