E42-349 · Corrosion Failure · Stainless steel flange · ★★

Problem Description

304 flange gasket crevice corrosion pits 2mm deep, leaking; 3 units repaired per month

Root Cause

[Crevice corrosion] Oxygen depletion in gasket crevice, Cl⁻ enrichment, crevice corrosion.
[Pit] Pit 2mm deep causing leakage.
[Design Omission] No corrosion-resistant gasket, no crevice sealant; safety factor only 1.3.

Corrective Solution

1) Replace with flexible graphite gasket;
2) Fill crevice with sealant;
3) Upgrade material to 316L;
4) Uniform bolt tightening;
5) Inspect crevices quarterly;
6) Control medium Cl⁻ to ≤50ppm;
7) Keep drainage unobstructed;
8) Replace gasket periodically.

Checklist

Reference

GB/T 9124.1-2019