Knowledge Base › Structural Design Error Case Study › Galvanic Corrosion at Aluminum-Steel Dissimilar Metal Joint

Galvanic Corrosion at Aluminum-Steel Dissimilar Metal Joint

E42-350 · Corrosion Failure · Aluminum-steel connector · ★★

Problem Description

Galvanic corrosion at aluminum housing-steel joint, rust layer loosened; 4 parts repaired per month

Root Cause

[Galvanic] Aluminum-steel potential difference 0.8V; large cathode and small anode; aluminum corrodes rapidly.
[Rust] Rust layer loosens and fails.
[Design Omission] No insulation, no coating; safety factor only 1.3.

Corrective Solution

1) Add insulating washers to break the circuit;
2) Coat contact faces with epoxy primer;
3) Anodize aluminum parts;
4) Choose materials with close potentials;
5) Quarterly inspection;
6) Drain to prevent pooling;
7)SealGuard;
8) Periodic replacement.

Checklist

Reference

GB/T 10125-2012