E42-350 · Corrosion Failure · Aluminum-steel connector · ★★
Galvanic corrosion at aluminum housing-steel joint, rust layer loosened; 4 parts repaired per month
[Galvanic] Aluminum-steel potential difference 0.8V; large cathode and small anode; aluminum corrodes rapidly.
[Rust] Rust layer loosens and fails.
[Design Omission] No insulation, no coating; safety factor only 1.3.
1) Add insulating washers to break the circuit;
2) Coat contact faces with epoxy primer;
3) Anodize aluminum parts;
4) Choose materials with close potentials;
5) Quarterly inspection;
6) Drain to prevent pooling;
7)SealGuard;
8) Periodic replacement.
GB/T 10125-2012