Knowledge Base › Structural Design Error Case Study › Erosion-Thinning of FGD Tower Spray Pipe

Erosion-Thinning of FGD Tower Spray Pipe

E42-432 · Corrosion Failure · Φ1200 FGD spray pipe · ★★★

Problem Description

Φ1200 FGD tower spray pipe (FRP-lined): slurry scouring erosion thinned wall from 8mm to 3mm and leaked slurry; repaired twice a year

Root Cause

[Erosion] Limestone slurry 15% solids, flow velocity 3m/s causing scouring. [Thinning] Wall thins 2.5mm per year, perforates in 3 years. [Design Omission] No wear-resistant lining, high flow velocity; safety factor 1.2 (should be ≥2.0).

Corrective Solution

1) Add wear-resistant ceramic lining inside;
2) Control flow velocity ≤2m/s;
3) Change material to duplex steel;
4) Measure thickness quarterly;
5) Control slurry concentration;
6) Add on-line wall thickness monitoring;
7) Optimize nozzles;
8) Replace at end of life.

Checklist

Reference

GB/T 50051-2013

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »