Impeller Damage by Cavitation plus Corrosion in Chemical Pump

E42-433 · Corrosion Failure · IH80-65-160 acid pump impeller · ★★★

Problem Description

IH80-65-160 pump (handling chloride medium): impeller cavitation pits 4mm deep plus corrosion, flow dropped 20%; 2 impellers replaced per month

Root Cause

[Cavitation] Insufficient inlet NPSH, bubble collapse causing pitting. [Corrosion] Cl⁻ medium uniform corrosion 0.3mm/a. [Damage] Impeller weight loss out of tolerance. [Design Omission] No higher NPSH, non-corrosion-resistant material; safety factor 1.2 (should be ≥1.8).

Corrective Solution

1) Raise inlet NPSH margin;
2) Change impeller to duplex stainless steel;
3) Add inducer;
4) Measure thickness quarterly;
5) De-gas the medium;
6) Impeller dynamic balance;
7) Limit cavitation margin;
8) Replace at end of life.