E42-439 · Corrosion Failure · 304 stainless steel reactor · ★★

Problem Description

304 reactor (with Cl⁻ cleaner): weld heat-affected zone pitting 1.5mm deep, leaking; repaired twice a month

Root Cause

[Pitting] Cl⁻ (200ppm) enriched, 304 not resistant, pitting rate 0.4mm/a. [Leakage] Wall 3mm thick, pitted through. [Design Omission] No 316L selected, no passivation; safety factor 1.2 (should be ≥2.0).

Corrective Solution

1) Change to 316L and pickle-passivate;
2) Control cleaner Cl⁻ to ≤50ppm;
3)Weld polishRa0.8;
4) Measure thickness quarterly;
5) Passivation film inspection;
6) Add corrosion inhibitor;
7) Limit temperature;
8) Replace at end of life.

Checklist

Reference

GB/T 24511-2017