E42-476 · Corrosion Failure · Heat exchanger tube bundle · ★★
Heat exchanger (316L) tube bundle: crevice corrosion perforation and leak, heat transfer dropped; repaired once a month
[Crevice corrosion] Tube-sheet gap pooled liquid enriched with Cl-, crevice corrosion perforation.
[Leak] Medium cross-contaminated.
[Design Omission] No dense expansion joint, no flushing; safety factor 1.3 (should be ≥2.0).
1) Tube-sheet expansion plus welding;
2) Upgrade material to 254SMO;
3) Add flushing openings;
4) Control Cl- to ≤50ppm;
5) Leak detection quarterly;
6)Cathodic protection;
7) Raise flow velocity to ≥1m/s;
8) Periodic re-measurement.
GB/T 151-2014