MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Structural Design Error Case Study › Pitting of Cooler Tube Bundle

Pitting of Cooler Tube Bundle

E42-528 · Corrosion Failure · Seawater cooler · ★★★

Problem Description

Tube bundle φ19×2: chloride pitting perforation and leak; replaced once a year

Root Cause

[Pitting] Cl-=20000ppm, passive film broken, pitting rate 0.5mm/a.
[Material] 304 not chloride-resistant.
[Design Omission] No duplex steel, no corrosion inhibitor; safety factor 1.2 (should be ≥2.0).

Corrective Solution

1) Change to 2205 duplex steel;
2) Add corrosion inhibitor;
3)Cathodic protection;
4) Leak check monthly;
5) Limit Cl-;
6) Coat/plate;
7) Control flow velocity;
8) Periodic thickness measurement.

Checklist

Reference

GB/T 24511-2017

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »