Arched Roof Truss Compression Chord Lateral Buckling

E42-191 · Structural Instability and Buckling · Steel arched roof truss · ★★

Problem Description

Arch-foot compression chord lateral deflected out of plane, deflection over L/500.

Root Cause

[Lateral deflection] Compression chord large slenderness, no lateral support. [Out-of-plane instability] Chord out-of-plane bending deflection over L/500. [Design Omission] No horizontal bracing, slenderness exceeded; truss deformed.

Corrective Solution

1. Add lateral support to compression chord.
2. Provide horizontal bracing system.
3. Control slenderness ≤120.
4. Enlarge chord section.
5. Stiffen gusset plate.
6. Check by out-of-plane stability.
7. Strengthen arch-foot anchorage.
8. Temporary support during installation.

Checklist

Reference

GB 50017-2017