E42-192 · Structural Instability and Buckling · Crane main girder upper flange · ★★★
Main girder compression flange locally buckled, web wrinkled, load capacity dropped 15%.
[Local buckling] Flange width-to-thickness B/t exceeded limit, local instability wrinkled. [Load capacity drop] Effective section reduced, load capacity dropped 15%. [Design Omission] Did not control B/t≤15, no stiffeners; girder sagged.
1. Control flange width-to-thickness ≤15.
2. Add longitudinal stiffener to flange.
3. Add transverse stiffener to web.
4. Local buckling FE analysis.
5. Enlarge flange thickness.
6. Pre-camber girder.
7. Load test measure deflection.
8. Rework out-of-tolerance girders.
GB 50017-2017