E42-316 · Structural Instability and Buckling · Hydraulic support leg · ★★★
Hydraulic support leg (Φ100×2000): compression buckled 15mm, support failed; 2 legs scrapped monthly
[Slenderness ratio] Slenderness λ=200 (should be ≤120), Euler critical Pcr=π²EI/L² low.
[Buckling] Working load exceeded Pcr, instability bend.
[Design Omission] No stability calculation, thin wall; safety factor only 1.1 (should be ≥2.0).
1) Reduce slenderness to ≤100 (upsize or shorten);
2) Raise wall thickness to 12mm;
3) Add intermediate guide bushing;
4) Upgrade material Q460;
5)Stability check;
6) Limit load;
7) Straightness check each batch;
8) Periodic NDE.
GB/T 25974.1-2010