E42-317 · Structural Instability and Buckling · Vacuum tank · ★★★
Vacuum tank (Φ1500×2000,δ=6): collapsed and deformed under vacuum; 1 unit scrapped monthly
[External-pressure instability] External pressure 0.1MPa, critical Pcr=0.06MPa below working.
[Collapse] Local dent 30mm deep.
[Design Omission] No external-pressure stability calculation, thin wall; safety factor only 1.1 (should be ≥2.0).
1) Raise wall thickness to 10mm;
2) Set stiffener-ring spacing ≤600mm;
3) Rib reinforcement;
4) Provide vacuum safety valve;
5)Stability check;
6) Limit vacuum degree;
7) Measure roundness each batch;
8) Pressure test.
GB/T 150.1-2011