Knowledge Base › Structural Design Error Case Study › Truss Chord Compression Buckling and Sagging

Truss Chord Compression Buckling and Sagging

E42-318 · Structural Instability and Buckling · Portal truss · ★★

Problem Description

Portal truss chord (L100×10): compression buckled, structure sagged; repaired once a month

Root Cause

[Chord buckling] Chord no lateral support, calculated length L=4m, λ=150 exceeded.
[Sag] Global stiffness dropped.
[Design Omission] No lateral support, small section; safety factor only 1.2 (should be ≥2.0).

Corrective Solution

1) Add lateral support to chord, spacing ≤2m;
2) Change section to H-beam;
3) Thicken gusset plate;
4) Global stability analysis;
5) Deformation check each batch;
6) Limit lifting load;
7) Corrosion protection;
8) Periodic inspection.

Checklist

Reference

GB 50017-2017