E43-342 · Thermal Deformation Not Compensated · A drum ∅800mm, designed balancing, measured rise 50℃ with distortion · ★★
A 50℃ drum temperature rise expands the diameter by 0.46mm, causing dynamic unbalance with vibration exceeding limits.
[Mechanism] Uneven thermal expansion of the drum destroys dynamic balance; centrifugal force excites vibration beyond the allowable limit.
[Calculation] α=11.5e-6, Δd=11.5e-6×800×50=0.46mm; the added eccentricity drives vibration over the limit.
[Design Omission] No temperature equalization or re-balancing — a design defect leading to excessive vibration.
1) Give the drum an even-temperature structure to hold the rise ≤20℃;
2) Re-balance hot to G2.5;
3) Add balance weights for the hot-state diameter growth;
4) Monitor vibration in real time with an alarm;
5) Use low-expansion drum material to reduce Δd;
6) Heat symmetrically to prevent distortion;
7) Re-check dynamic balance periodically;
8) Measure first-article vibration to verify ≤2.8mm/s.
GB/T 10895-2016 Centrifuges — Vibration