Weld Shrinkage Shortens the Truss Axis Spacing

E43-098 · Weld/Cast Forming Out of Tolerance · Truss Welding · ★★

Problem Symptom

Weld seam shrinkage shortened the axis spacing by 0.50, so the assembly holes were misaligned

Root Cause

[Shrinkage] Longitudinal shrinkage of the weld seams shortened the overall length by 0.50.
[Misalignment] The shrinkage shifted the connecting hole spacing so the bolts would not pass.
[Design Omission] Weld shrinkage allowance should have been provided with segment welding, but no shrinkage calculation was made.

Correct Solution

1) Allow 0.50 of shrinkage allowance;
2) Weld in symmetric segments;
3) Carry out a shrinkage calculation;
4) Use an assembly jig;
5) Correct the distortion after welding;
6) Measure the spacing on the first piece;
7) Drill the holes to match after assembly;
8) Correct out-of-specification parts.

Checklist

References

GB/T 19804-2003 General Tolerances for Welded Structures