E43-352 · Welded/Cast Forming Dimensional Error · A press crosshead web 600mm wide, 20mm thick, designed post-weld flatness ≤0.5, measured angular distortion 2.6 · ★★
Flange-weld angular distortion pushes web flatness 2.6mm out of tolerance and misaligns the ram guide.
[Mechanism] Uneven transverse shrinkage of a one-sided weld produces angular distortion; the web warps toward the weld side and leaves the theoretical plane.
[Calculation] Angular distortion f=B·θ/2=600×tan1°/2≈600×0.0175/2≈5.2mm (net 2.6mm measured after both sides offset).
[Design Omission] No double-sided symmetric welding or distortion-control tooling — a design defect leading to flatness error.
1) Weld double-sided symmetrically in segments to reduce angular distortion;
2) Use an anti-distortion fixture to pre-bend and offset 2.6mm;
3) Add temporary rigid stiffeners before welding;
4) Flame-straighten flatness after welding;
5) Control heat input ≤20kJ/cm;
6) Symmetrically lay out welds to reduce twisting;
7) Stress-relief anneal after welding;
8) Measure first-article flatness ≤0.5mm.
JB/T 8609-2016 Forging and stamping machinery — Welded parts — Technical specifications