E43-360 · Welded/Cast Forming Dimensional Error · An H-section with 300mm flange width, designed web perpendicularity ≤1, measured 3.2 · ★★

Problem Description

Flange-weld angular distortion pushes web perpendicularity 3.2mm out of tolerance and twists the beam.

Root Cause

[Mechanism] Uneven transverse shrinkage of the flange-to-web weld produces angular distortion, tilting the web off vertical.
[Calculation] Perpendicularity deviation Δ=B·tanθ=300×tan0.6°≈300×0.0105≈3.1mm (measured 3.2).
[Design Omission] No double-sided boat-position welding or flange straightening — a design defect leading to perpendicularity error.

Corrective Solution

1) Weld double-sided symmetrically in boat position to reduce angular distortion;
2) Straighten the flange on a straightener after welding;
3) Apply an anti-distortion pre-bend;
4) Control heat input ≤18kJ/cm;
5) Add temporary rigid bracing;
6) Stress-relieve after welding;
7) Check perpendicularity with a square;
8) Measure first-article perpendicularity ≤1mm.

Checklist

Reference

GB/T 11263-2017 Hot-rolled H sections