E43-361 · Welded/Cast Forming Dimensional Error · A centrifugal pump body with 400mm flange, designed flange flatness 0.05, measured flash 0.3 · ★★
Casting parting-line flash pushes the flange sealing-face flatness 0.3mm out of tolerance and leaks in the hydrostatic test.
[Mechanism] Residual parting-line flash on the flange face forms local protrusions; the sealing face is not flat, causing leakage.
[Calculation] Flash height h≈0.3mm makes flatness error 0.3, 6× the tolerance of 0.05.
[Design Omission] The parting line was not set to clear the flange face, and flash was not removed — a design defect leading to flatness error.
1) Set the parting line away from the flange sealing face;
2) Clean thoroughly to remove all flash;
3) Finish-machine the flange face to hold flatness;
4) Provide evenly distributed process pads;
5) Improve mold parting accuracy;
6) Check flatness on a surface plate by scraping;
7) Verify sealing in the hydrostatic test;
8) Measure first-article flatness ≤0.05mm.
GB/T 3216-2016 Rotodynamic pumps — Hydraulic performance acceptance tests