MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Pump-Body Casting Mold Flash Causing Flange-Face Flatness Error

Pump-Body Casting Mold Flash Causing Flange-Face Flatness Error

E43-361 · Welded/Cast Forming Dimensional Error · A centrifugal pump body with 400mm flange, designed flange flatness 0.05, measured flash 0.3 · ★★

Problem Description

Casting parting-line flash pushes the flange sealing-face flatness 0.3mm out of tolerance and leaks in the hydrostatic test.

Root Cause

[Mechanism] Residual parting-line flash on the flange face forms local protrusions; the sealing face is not flat, causing leakage.
[Calculation] Flash height h≈0.3mm makes flatness error 0.3, 6× the tolerance of 0.05.
[Design Omission] The parting line was not set to clear the flange face, and flash was not removed — a design defect leading to flatness error.

Corrective Solution

1) Set the parting line away from the flange sealing face;
2) Clean thoroughly to remove all flash;
3) Finish-machine the flange face to hold flatness;
4) Provide evenly distributed process pads;
5) Improve mold parting accuracy;
6) Check flatness on a surface plate by scraping;
7) Verify sealing in the hydrostatic test;
8) Measure first-article flatness ≤0.05mm.

Checklist

Reference

GB/T 3216-2016 Rotodynamic pumps — Hydraulic performance acceptance tests

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL